Automation Pioneer

Prosoft Network Interface Module MVI56-MBP

The MVI56-MBP Modbus Plus Communication Module allows ControlLogix compatible processors to interface easily with other Modbus Plus protocol compatible devices.

The Modbus Plus module is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others).

Compatible devices include not only Modicon PLCs (which all support the Modbus Plus protocol) but also a wide assortment of end devices licensed through the ModConnect Program. The MVI56-MBP module acts as an input/output module between the Modbus Plus network and the ControlLogix backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the Modbus Plus network.A 4000-word register space in the module exchanges data between the processor and the Modbus Plus network.

These modules allow platforms to connect directly on Modbus Plus networks as a peer. In addition, the modules act as slaves to processors that must read/write data from the module’s memory.

Crossing all industrial boundaries, potential applications include the connection of processors to Modicon processors, and the connection of Modbus Plus speaking devices such as drives, relays, and power monitor hardware to the ControlLogix backplanes.

Category:

Description

Prosoft Network Interface Module MVI56-MBP

  • Extended Product Type : ASCII
  • Product ID: MVI56-MBP
  • Prosoft Type Designation : ASCII

Features and Benefits

  • Single Slot – 1756 backplane compatible
  • Local or remote rack
  • The MVI56-MBP is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module.
  • Ladder Logic is used for data transfer between module and processor.
  • Configuration data obtained through user-defined ladder. Sample ladder file included.

Specification

  • Communication parameters (Config port only)
    • Baud: 57,600 (fixed)
    • Parity: none (fixed)
    • Stop: 1 (fixed)
  •  Modbus Plus ports
    • Memory usage is user definable
    • Support for the storage and transfer of up to 4,000 registers across the backplane
    • 100 word reads and writes (max. allowed)
    • Supports all five levels of Modbus Plus routing
    • Software configurable parameters Node address: 1 to 64
    • Global out size: 0 to 32 words
    • Global in size: 0 to 32 words
    • Module data transfer: 0 to 4,000 words
    • Master command count: 0 to 200 commands
  • Function codes accepted (as a Slave): 1, 2, 3, 4, 5, 6, 15, 16
  • Function codes transmitted (as a Master): 3, 16

 

Brand

Prosoft

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.